Product Details:
Payment & Shipping Terms:
|
Standard: | BS 6724 | Sample: | 0.2m Free Of Charge |
---|---|---|---|
Jacket: | LSZH | Conductor Operating Temp: | 90 ℃ |
Rated Voltage: | 600/1000V | Sheath Color: | Orange |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | low smoke halogen free cable,lszh power cable |
Copper Conductor Multi Core SWA BS 6724 0.6/1kV LSZH Cable
Halogen free cable/wire, also called zero halogen cable, refers to cables where the cable jacketing and insulation is made with materials that produce no toxic halogens when exposed to fire or high temperatures. These halogen free cables are used when smoke considerations are minimal. Halogen-free cables also do not use materials that may have an environmental impact.
Low smoke cable/wire, also called limited smoke cable, refers to cables where the cable jacketing and insulation is made with materials that produce no or only small amounts of smoke when exposed to fire or high temperatures. These low smoke cables are used when halogen considerations are minimal.
Applications
Single core LSZH cable with aluminium wire armour (AWA). Power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
Construction
Conductor Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360) Insulation XLPE (Cross-Linked Polyethylene) Type GP8 according to BS 7655 Bedding LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655 Armour AWA (Aluminium Wire Armour) Sheath LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655
Standards:
BS 6724, BS EN/IEC 60502-1, BS EN/IEC 60754-1 and 2 BS EN 50267-2-1 and 2, BS EN/IEC 61034-1, BS EN/IEC 60332-1-2, BS EN/IEC 60332-3-24.
Certificates
ISO,CE, KEMA ,IEC, CCC, P3C and more others at request
Abbreviation Meaning:
LSZH Low smoke, zero halogen LSF Low smoke, fume LS0H Low smoke, zero halogen LSHF Low smoke, halogen free LSNH Low smoke, nonhalogen NHFR Nonhalogen, flame retardant HFFR Halogen free, flame retardant FRNC Fire retardant, noncorrosive LS Low, limited smoke ST Smoke test (limited smoke) FRLS Fire resistant, low smoke RE Reduced emissions LC Low corrosivity LH Low halogen
LSZH materials for low-smoke properties and reduced toxicity
Tinned copper conductors resist corrosion
Stranded conductors for installation flexibility
Multiconductor and multipair configurations
Unshielded versions for smallest diameter
Foil shielded, overall or individual pairs, for EMI protection and improved signal integrity
Color-coded conductor insulation for easy identification
Nominal cross sectional area mm² | Approx. overall diameter mm | Approx. Dia. Under Armour mm | Nominal diameter of armour wires mm | Approx. cable weight kg/km | Maximum conductor resistance @ 20°C Ohms/km | Conductor short circuit rating (1 sec) kA | Three phase AC clipped direct | Three phase AC trefoil touching free air Amps | Volt drop Three phase AC mV/A/m |
1.5 | 12 | 8 | 0.9 | 280 | 12.1 | 0.20 | 23 | 25 | 27 |
2.5 | 13 | 9 | 0.9 | 350 | 7.41 | 0.35 | 31 | 33 | 16 |
4 | 15 | 10 | 0.9 | 450 | 4.61 | 0.57 | 42 | 44 | 10 |
6 | 16 | 11 | 0.9 | 550 | 3.08 | 0.86 | 53 | 56 | 6.8 |
10 | 18 | 13 | 1.25 | 800 | 1.83 | 1.4 | 73 | 78 | 4 |
16 | 21 | 15 | 1.25 | 1110 | 1.15 | 2.2 | 94 | 99 | 2.5 |
25 | 26 | 19 | 1.6 | 1700 | 0.727 | 3.6 | 124 | 131 | 1.65 |
35 | 28 | 22 | 1.6 | 2100 | 0.524 | 5.0 | 154 | 162 | 1.15 |
50* | 30 | 23 | 1.6 | 2400 | 0.387 | 7.1 | 187 | 197 | 0.87 |
70* | 34 | 26 | 1.6 | 3100 | 0.268 | 10.0 | 238 | 251 | 0.6 |
95* | 36 | 29 | 2 | 4100 | 0.193 | 13.6 | 289 | 304 | 0.45 |
120* | 40 | 32 | 2 | 5000 | 0.153 | 17.2 | 335 | 353 | 0.37 |
150* | 45 | 36 | 2.5 | 6300 | 0.124 | 21.4 | 386 | 406 | 0.3 |
185* | 49 | 40 | 2.5 | 7600 | 0.00991 | 26.5 | 441 | 463 | 0.26 |
240* | 54 | 44 | 2.5 | 9600 | 0.0754 | 34.3 | 520 | 546 | 0.21 |
300* | 59 | 49 | 2.5 | 11600 | 0.0601 | 42.9 | 599 | 628 | 0.185 |
400* | 65 | 55 | 2.5 | 14400 | 0.047 | 57.2 | 673 | 728 | 0.165 |
Packing and shipping
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.